BS Standard Bare Overhead Conductor ACSR for 132kv Transmission Line

Model NO.: zx-42
Material Shape: Round Wire
Range of Application: Flame Retardant
Certification: ISO9001, CE, CCC
Trademark: OEM
Transport Package: in Coils on Spool
Origin: Hebei China
HS Code: 7312100000
Model NO.: zx-42
Material Shape: Round Wire
Range of Application: Flame Retardant
Certification: ISO9001, CE, CCC
Trademark: OEM
Transport Package: in Coils on Spool
Origin: Hebei China
HS Code: 7312100000
Aluminium Conductor Steel Reinforced (ACSR)
Aluminium Conductor Steel Reinforced (ACSR) is concentrically stranded conductor with one or more layers of hard drawn 1350-H19 aluminium wire on galvanized steel wire core. The core can be single wire or stranded depending on the size. Steel core wire is available in Class A , B or Class C galvanization for corrosion protection. Additional corrosion protection is available through the application of grease to the core or infusion of the completed conductor with grease.

The proportion of steel and aluminium in an ACSR conductor can be selected based on the mechanical strength and current carrying capacity demanded by each application.

ACSR conductors are recognized for their record of economy, dependability and favourable strength / weight ratio. ACSR conductors combine the light weight and good conductivity of aluminium with the high tensile strength and ruggedness of steel. In line design, this can provide higher tensions, less sag, and longer span lengths than obtainable with most other types of overhead conductors.

Midal manufacture and supply ACSR on Non-Returnable wooden/steel reels or Returnable steel reels depending on customer requirement.

ACSR Wire Strand(Galvanized Steel Strand)
1) Material:    high carbon.(Galvanized Steel Strand)
2) Construction: 7-wire strand 19-wire strand 37-wire strand 61-wire strand
3) Strand sizes:  0.234-0.745" (5.94 mm-18.92 mm)
4) Surface: Galvanization in Coating Classes A or B.(Galvanized Steel Strand)
5) Packing: in coils, on spool
6)Standard: ASTM B500, ASTM A475 .(Galvanized Steel Strand)
7) All can be produced according to customers' actual requirement.

Features
high Tensile strength
better sag properties
economic design
best suited for transmission lines with long spans

Application
Used for mechanical re-inforcement in the manufacture of aluminum conductor steel reinforced(ACSR) Cable & Conductor ACSR Core wire is used in reinforcement of aluminium conductors used in distribution and transmission of electricity. ACSR Core strand.


ACSR photo
BS Standard Bare Overhead Conductor ACSR for 132kv Transmission Line
BS Standard Bare Overhead Conductor ACSR for 132kv Transmission Line
BS Standard Bare Overhead Conductor ACSR for 132kv Transmission Line
                                
Technical data
ACSR Technical Characteristics Based on Standard BS 215-2   
 
Code name Nominal aluminium area Stranding and wire     diameter Sectional area of aluminium Total sectional area Approx. overall diameter Approx. mass Calculated D.C. resistance at 20oC Calculated breaking load
Al Steel
mm2 No./mm mm2 mm2 mm kg/km Ω/km kN
RABBIT 50 6/3.35 1/3.35 52.88 61.7 10.05 214 0.5426 18.35
DOG 100 6/4.72 7/1.57 105 118.5 14.15 394 0.2733 32.7
WOLF 150 30/2.59 7/2.59 158.1 194.9 18.13 726 0.1828 69.2
DINGO 150 18/3.35 1/3.35 158.7 167.5 16.75 506 0.1815 35.7
LYNX 175 30/2.79 7/2.79 183.4 226.2 19.53 842 0.1576 79.8
ZEBRA 400 54/3.18 7/3.18 428.9 484.5 28.62 1621 0.0674 131.9

Our service

· The sample is free.
· The quality of our products are qualified.
· Our delivery speed will be the fastest.
· We can provide the most professinal technical guidance and service

FAQ
1. How about the delivery time?
    Lead time since receipt of 30% T/T deposit payment: 3 weeks. 
2. What's are the MOQ?
    We can according to your condition to set the MOQ.
    And we can provide you samples for quality inspection.
 
3. How to deal with the sample charge?
    Accordeing to our company policy, the samples are free, we only charge the freight fee.And we will return the freight fee If you set the order.
 
4. Can you produce the product according to customers' requirements?
  Sure, we are professional manufacturer, OEM and ODM are both welcome.
BS Standard Bare Overhead Conductor ACSR for 132kv Transmission Line
BS Standard Bare Overhead Conductor ACSR for 132kv Transmission Line
BS Standard Bare Overhead Conductor ACSR for 132kv Transmission Line



 
Aluminium Conductor Steel Reinforced (ACSR)
Aluminium Conductor Steel Reinforced (ACSR) is concentrically stranded conductor with one or more layers of hard drawn 1350-H19 aluminium wire on galvanized steel wire core. The core can be single wire or stranded depending on the size. Steel core wire is available in Class A , B or Class C galvanization for corrosion protection. Additional corrosion protection is available through the application of grease to the core or infusion of the completed conductor with grease.

The proportion of steel and aluminium in an ACSR conductor can be selected based on the mechanical strength and current carrying capacity demanded by each application.

ACSR conductors are recognized for their record of economy, dependability and favourable strength / weight ratio. ACSR conductors combine the light weight and good conductivity of aluminium with the high tensile strength and ruggedness of steel. In line design, this can provide higher tensions, less sag, and longer span lengths than obtainable with most other types of overhead conductors.

Midal manufacture and supply ACSR on Non-Returnable wooden/steel reels or Returnable steel reels depending on customer requirement.

ACSR Wire Strand(Galvanized Steel Strand)
1) Material:    high carbon.(Galvanized Steel Strand)
2) Construction: 7-wire strand 19-wire strand 37-wire strand 61-wire strand
3) Strand sizes:  0.234-0.745" (5.94 mm-18.92 mm)
4) Surface: Galvanization in Coating Classes A or B.(Galvanized Steel Strand)
5) Packing: in coils, on spool
6)Standard: ASTM B500, ASTM A475 .(Galvanized Steel Strand)
7) All can be produced according to customers' actual requirement.

Features
high Tensile strength
better sag properties
economic design
best suited for transmission lines with long spans

Application
Used for mechanical re-inforcement in the manufacture of aluminum conductor steel reinforced(ACSR) Cable & Conductor ACSR Core wire is used in reinforcement of aluminium conductors used in distribution and transmission of electricity. ACSR Core strand.


ACSR photo
BS Standard Bare Overhead Conductor ACSR for 132kv Transmission Line
BS Standard Bare Overhead Conductor ACSR for 132kv Transmission Line
BS Standard Bare Overhead Conductor ACSR for 132kv Transmission Line
                                
Technical data
ACSR Technical Characteristics Based on Standard BS 215-2   
 
Code name Nominal aluminium area Stranding and wire     diameter Sectional area of aluminium Total sectional area Approx. overall diameter Approx. mass Calculated D.C. resistance at 20oC Calculated breaking load
Al Steel
mm2 No./mm mm2 mm2 mm kg/km Ω/km kN
RABBIT 50 6/3.35 1/3.35 52.88 61.7 10.05 214 0.5426 18.35
DOG 100 6/4.72 7/1.57 105 118.5 14.15 394 0.2733 32.7
WOLF 150 30/2.59 7/2.59 158.1 194.9 18.13 726 0.1828 69.2
DINGO 150 18/3.35 1/3.35 158.7 167.5 16.75 506 0.1815 35.7
LYNX 175 30/2.79 7/2.79 183.4 226.2 19.53 842 0.1576 79.8
ZEBRA 400 54/3.18 7/3.18 428.9 484.5 28.62 1621 0.0674 131.9

Our service

· The sample is free.
· The quality of our products are qualified.
· Our delivery speed will be the fastest.
· We can provide the most professinal technical guidance and service

FAQ
1. How about the delivery time?
    Lead time since receipt of 30% T/T deposit payment: 3 weeks. 
2. What's are the MOQ?
    We can according to your condition to set the MOQ.
    And we can provide you samples for quality inspection.
 
3. How to deal with the sample charge?
    Accordeing to our company policy, the samples are free, we only charge the freight fee.And we will return the freight fee If you set the order.
 
4. Can you produce the product according to customers' requirements?
  Sure, we are professional manufacturer, OEM and ODM are both welcome.
BS Standard Bare Overhead Conductor ACSR for 132kv Transmission Line
BS Standard Bare Overhead Conductor ACSR for 132kv Transmission Line
BS Standard Bare Overhead Conductor ACSR for 132kv Transmission Line



 

65W Power Bank

power bank

Power Bank is a portable charger that can be carried by individuals and reserves power by itself. It is mainly used to charge consumer electronic products such as handheld mobile devices (such as wireless phones and laptops), especially when there is no external power supply. Its main components include: a battery for electrical energy storage, a circuit (DC-DC converter) to stabilize the output voltage, and most mobile power supplies come with a charger for charging as a built-in battery.

Whaylan always adhere to the concept of "innovation drives development, science and technology leads the future", product research and development is quality-oriented, efficient-based, safety-oriented as the principle, the establishment of a strong, experienced R & D team, the company has been rated as science and technology small and medium-sized enterprises, specialized new enterprises, high-tech enterprises.

ince its establishment, the company has always adhered to the original intention of "let the whole world use clean energy", deeply plough into the field of power, electronic and electric energy transformation, and is committed to providing smart energy management and other overall solutions for families, industrial and commercial users and ground power stations with innovative technology, excellent products and professional services.




65W Power Bank,best power bank 20000mah,best power banks,portable charger

suzhou whaylan new energy technology co., ltd , https://www.whaylanenergy.com

Posted on