This reagent is for research use only: serum or plasma
Shanghai Enzyme Biotechnology Co., Ltd. specializes in supplying dextran gel HL-20, interleukin elisa kit, tumor necrosis factor elisa kit, human leucoplasma B27, cell growth factor kit, providing free testing services to ensure experiments The result is objective and authentic. Our company guarantees 100% quality of the kit. If there are quality problems, we will return the unconditional package.
Test principle:
The p53 kit is a solid phase sandwich enzyme-linked immunosorbent assay (ELISA). It is known that a standard of p53 concentration and a sample of unknown concentration are added to a microplate. P53 and biotinylated antibodies were first incubated simultaneously. After washing, avidin-labeled HRP was added. After incubation and washing, the unbound enzyme conjugate is removed, then the substrates A, B, and the enzyme conjugate are added simultaneously. Produce color. The depth of the color is proportional to the concentration of p53 in the sample.
Safety Avoid direct contact with the stop solution and substrates A, B. Once exposed to these liquids, rinse with water as soon as possible.
Do not eat, drink, smoke or use cosmetics during the experiment.
Do not use your mouth to take any ingredients from the kit.
Human p53 ELISA test kit
Handling Precautions Reagents should be stored according to the label instructions and returned to room temperature before use. Standards after dilution should be discarded and cannot be stored.
The slats not used in the experiment should be immediately put back into the bag and sealed to prevent deterioration.
Other reagents not used should be packaged or covered. Do not mix reagents of different batches. Use before warranty.
Use a disposable tip to avoid cross-contamination. Avoid pipettes with metal parts when drawing stop solution and substrate A and B.
Use a clean plastic container to configure the wash solution. Mix all the ingredients and samples in the kit thoroughly before use.
Wash the enzyme plate should be fully patted dry, do not put the absorbent paper directly into the enzyme standard reaction well to absorb water.
Substrate A should be volatilized to avoid opening the lid for extended periods of time. Substrate B is sensitive to light and avoids prolonged exposure to light. Avoid contact with hands and be toxic. The OD value should be read immediately after the experiment is completed.
The order of addition of reagents should be consistent to ensure that all wells are incubated for the same time.
The incubation was carried out according to the time indicated in the instructions, the amount of addition and the order.
Sample Collection, Handling, and Preservation Methods Serum—avoid any cell stimulation during the procedure. Use tubes without pyrogens and endotoxins. After collecting the blood, the serum and red blood cells were quickly and carefully separated by centrifugation at 1000 x g for 10 minutes.
Plasma-----EDTA, citrate, heparin plasma can be used for detection. The pellet was removed by centrifugation at 1000 x g for 30 minutes.
The cell supernatant - 1000 x g was centrifuged for 10 minutes to remove particles and polymer.
Tissue homogenization ----- tissue is added to the appropriate amount of physiological saline. Centrifuge at 1000 × g for 10 minutes, and take the supernatant for storage. ------ If the sample is not used immediately, it should be divided into small portions at -70 °C to avoid repeated freezing. Do not use hemolysis or hyperlipemia as much as possible. If there are large amounts of particles in the serum, centrifuge or filter before testing. Do not heat thaw at 37 ° C or higher. It should be thawed at room temperature and ensure that the sample is fully thawed evenly.
Human p53 ELISA test kit
Mix all reagents thoroughly before using. Do not allow the liquid to generate a large amount of foam, so as to avoid adding a large amount of air bubbles during the loading, resulting in errors in the loading.
The number of slats required is determined by the number of samples to be tested plus the number of standards. Multiple holes are recommended for each standard and blank hole. Each sample is determined according to its own quantity, and it is possible to use the double hole as much as possible to make a double hole. The specimen was diluted 1:1 with the specimen dilution and 50 ul was added to the reaction well.
50 ul of the diluted standard was added to the reaction well, and 50 ul of the sample to be tested was added to the reaction well. Immediately add 50 ul of biotinylated antibody. Cover the membrane, mix gently by shaking, and incubate for 1 hour at 37 °C.
Remove the liquid from the well, fill each well with the washing solution, shake for 30 seconds, remove the washing solution, and pat dry with absorbent paper. Repeat this operation 3 times. If washing with a washer, the number of washings is increased once.
80 ul of affinity streptavidin-HRP was added to each well, and the mixture was gently shaken and incubated at 37 ° C for 30 minutes.
Remove the liquid from the well, fill each well with the washing solution, shake for 30 seconds, remove the washing solution, and pat dry with absorbent paper. Repeat this operation 3 times. If washing with a washer, the number of washings is increased once.
Add 50 μl of each of the substrates A and B to each well, mix gently by shaking, and incubate at 37 ° C for 10 minutes. Avoid lighting.
Remove the microplate and quickly add 50 ul of stop solution. Immediately after adding the stop solution, the results should be determined.
The OD value of each well was measured at a wavelength of 450 nm.
The results above the No. 6 standard are non-linear and no accurate results can be obtained from this standard curve.
Kit performance
1. Sensitivity: The minimum detection concentration is less than the No. 1 standard. The linearity of the dilution. The linear regression coefficient of the sample and the expected concentration correlation coefficient R value was 0.990.
2. Specificity: Does not react with other cytokines.
3. Repeatability: The coefficient of variation between the plate and the plate is less than 10%.
Human p53 ELISA test kit
Result judgment and analysis
1. Instrument value: read the OD value of each hole on a microplate reader with a wavelength of 450 nm.
2. The absorbance OD value is the ordinate (Y), and the corresponding p53 standard concentration is the abscissa (X), and the corresponding curve is obtained. The p53 content of the sample can be converted into the corresponding concentration according to the OD value from the standard curve.
3. Detection range: 0-80ng/ml
4. Sensitivity: 0.1 ng/ml
Goat anti-Guinea pig IgG/Gold gold-labeled goat anti-guinea pig IgG (10nm/15nm) 1ml
Goat anti-rabbit IgG/Glod gold-labeled goat anti-rabbit IgG (10nm/15nm) 0.5ml
Goat anti-rabbit IgG/Glod gold-labeled goat anti-rabbit IgG (10nm/15nm) 1ml
IL-21 (Interleukin-21) Interleukin 21 Antibody 0.2ml
IL-21R (Interleukin-21 receptor) Interleukin 21 Receptor Antibody 0.2ml
IL-22/ZCYTO18 (Interleukin-22) Interleukin-22 Antibody 0.2ml
IL-22R/IL22RA1 (Interleukin-22 receptor subunit alpha-1) Interleukin-22 Receptor Antibody 0.2ml
IL-22BP/IL22RA2 (Interleukin-22 receptor subunit alpha-2) Interleukin 22 receptor binding protein antibody 0.2ml
IL1RAPL1 (Interleukin 1 receptor accessory protein-like 1) Interleukin receptor-associated protein-like 1 precursor protein antibody 0.2ml
IL-26/AK155 (Interleukin-26/Protein AK155 ) Interleukin 26 Antibody 0.2ml
Mouse anti-Goat IgM/Gold Gold-labeled mouse anti-goat IgM (10nm/15nm) 2ml
Mouse anti-human IgG/Gold Gold-labeled mouse anti-human IgG (10nm/15nm) 2ml
Mouse anti-human IgM/Gold Gold-labeled mouse anti-human IgM (10nm/15nm) 2ml
IL-28A/IFNL2 (Interleukin 28/Interferon lambda-2) Interleukin 28A Antibody 0.2ml
IL-28B/IL-28C/IFNL3/IFNL4 (Interleukin-28B) Interleukin 28B Antibody 0.2ml
IL-29/IFNL1 (Interleukin-29/Interferon lambda-1) Interleukin 29 Antibody 0.2ml
IL-31 (Interleukin-31) Interleukin 31 Antibody 0.2ml
IL-31RA/CRL3 (Interleukin-31 receptor subunit alpha) Interleukin 31 Receptor a Antibody 0.2ml
As a mobile multi-purpose platform, tablet computers also provide many possibilities for mobile teaching. The touch-based learning & entertainment teaching platform allows children to efficiently improve their academic performance in a relaxed and pleasant atmosphere. Such tablet computers generally integrate two learning sections of various courses and systematic learning functions. Generally, it includes multi-disciplinary high-quality teaching resources. The education tablet has the following main functions: it has the functions of touch screen input, text editing, picture editing, data storage, data management, wired and wireless Internet access that ordinary tablet computers have; Management functions, search methods support manual search, query by keyword, query by time; text and pictures can be scanned and converted into documents to save.
Education Tablet,learning tablet,leaning machine,New learning tablet
Jingjiang Gisen Technology Co.,Ltd , https://www.jsgisengroup.com